Fluazifop-P-butyl
Content Handbook G
Outline of method
The sample is dissolved in solvent containing benzil as internal standard. Separation is carried out by high performance liquid chromatography using a silica column with (R)-3,5-dinitrobenzoylphenylglycine as the covalently bonded stationary phase. The fluazifop-P butyl is determined by comparison with calibration solutions.
Scope
The method is usable for TC, WG, EC, EW and EC formulations.