CIPAC No / name
|
Description
|
Status
|
Published |
|
454 alpha-cypermethrin
|
The soap washing method for the determination of the remaining active ingredient concentration remains a tentative MT method because of the ongoing general work on LN washing method(s)
|
tentative
|
LN-method, download click
here
|
|
738 clothianidin
|
The reversed phase HPLC method (CIPAC/4658) for the determination of clothianidin in TC, WG, SC, GR and SG formulations accepted as a full CIPAC method, subject to changing the injection volume to 5 µl, to modify the sample preparation in the case of SC and SG formulations by adding water and introducing a footnote to the column drawing attention to the shape of the peak. |
full
|
prepublished
method |
| 738 clothianidin
|
The extension of the scope of the HPLC method (CIPAC/4658) for the determination of clothianidin in FS and WS formulations (CIPAC/4692) was accepted as a provisional CIPAC method. |
provisional |
no |
|
333
deltamethrin
|
The method for the determination of wash retention of LN formulations remains a provisional washing MT method because of the ongoing general work on LN washing method(s). |
provisional |
LN-method,
download click here |
| 333 deltamethrin
|
The
extension of the scope of CIPAC method 333 (CIPAC/4673) for the determination of the total content of deltamethrin in incorporated PE LN formulations remains as a provisional CIPAC method as additional information, clarification is requested from the company. |
provisional
|
LN-method,
download click here |
|
739 dimoxystrobin
|
The capillary GC method (CIPAC/4710) for the determination of the content of dimoxystrobin in TC, SE and SC formulations was accepted as a provisional CIPAC method |
provisional
|
no |
| 521 fluazinam
|
The reversed phase HPLC method (CIPAC/4727) for the determination of fluazinam in TC and SC formulations was accepted as a provisional CIPAC method . |
provisional |
no |
| 463 lambda cyhalothrin
|
The extension of the scope of CIPAC method 463 (CIPAC/4664) for the determination of the content of lambda cyhalothrin in LN formulations was accepted as a full CIPAC method. |
full
|
no |
| 767 1-methylcyclopropene (1-MCP)
|
The capillary GC method (CIPAC/4669) for the determination of 1- methylcyclopropene in the SmartFresh 3.3% vapour-releasing product remains as a provisional CIPAC method. |
provisional
|
prepublished method |
|
331 permethrin
|
The "washing method" (CIPAC/4503) remains as a tentative MT method because of the ongoing general work on LN washing method(s). |
tentative
|
LN-method, download click
here
|
| 331 permethrin |
The extension of the scope of CIPAC method 331/TC/M/3 (CIPAC/4503) for the determination of the content of permethrin in EC formulations was accepted as a provisional CIPAC method. |
provisional |
no |
|
33 piperonyl butoxide
|
The method extension to the capillary GC method (AOAC-CIPAC 32+33+345/TK(M)) (CIPAC/4675) for the determination of piperonyl butoxide in
incorporated PE LN formulations remains as a provisional CIPAC method. |
provisional |
LN-method,
download click here |
|
636 spinosad
|
The extension of the scope of CIPAC method 636/TC/M/3 for the determination of the content of spinosad in EC formulations was accepted as a provisional CIPAC method, with a footnote that mineral oil is not causing clogging of the column. |
provisional
|
no |
| 352 triadimefon
|
The extension of the scope of CIPAC method 352 (CIPAC/4689) for the determination of the content of triadimefon in EC, WG and GR formulations was accepted as a full CIPAC method. |
full |
prepublished method |
| 398 triadimenol |
The extension of the scope of CIPAC method 398 (CIPAC/4687) for the determination of the content of triadimenol in SC, FS and EW formulations was accepted as a full CIPAC method. |
full
|
prepublished method |
| MT 41
|
Changes proposed to method MT 41 (CIPAC/4732) were accepted and will be published on the CIPAC web site |
accepted |
no |
| MT 172
|
Changes proposed to method MT 172.1 (CIPAC/4733) were accepted and will be published on the CIPAC web site
In addition it was accepted to extend the method to all accelerated storage schemes according to MT 46.3 with no need for collaborative trial. |
accepted |
no |
| MT 193 |
Changes proposed to method MT 193 (CIPAC/4731) were accepted and will be published on the CIPAC web site
The title of the method MT 193 was changed to Attrition of tablets. |
accepted
|
no
|