Content of Handbook M


Pendimethalin [357]

OUTLINE OF METHOD

The pendimethalin is determined by reversed phase high performance liquid chromatography using a silica column loaded with 17 % carbon, using UV detection at 235 nm and external standardisation.


SCOPE:

The method is usable for TC and EC-formulations.