Content
Handbook J
MT 46.3 ACCELERATED
STORAGE PROCEDURE
OUTLINE OF METHOD
A sample is
placed in a glass bottle (or another suitable container), which is
subsequently closed and placed in an oven at a specified temperature
for a defined period of time.
SCOPE:
The
objective is to simulate the normal long-term ageing of a formulation
by heating. Although actual data from a product in sales packs and
stored in e.g. warehouses is preferable, the accelerated storage test
provides useful guidance on performance after storage since many formulations
that perform poorly in the accelerated test do not have satisfactory
shelf lives (of at least 2 years) in hot or temperate climates.
The mehod is usable for solid and liquid formulations.