Content
Handbook J
Hexazinone
OUTLINE OF METHOD
Hexazinone
is determined by high performance liquid chromatography on a reversed
phase column (C8) using water (at pH 3) - acetonitrile 50 + 50 (v/v)
as eluent and UV detection at 254 nm. The content of active ingredient
is quantified using a calibration curve.
SCOPE:
The method
is usable for TC, WG, SP, SL and SG-formulations