Content
Handbook H
GLYPHOSATE
OUTLINE OF METHOD
The sample is dissolved in a phosphate buffered mobile
phase and the glyphosate is determined by high performance liquid
chromatography using a ion exchange column, UV detection at 195 nm,
and external standardisation.
SCOPE:
For the method
see Handbook C. The method extension is for SG-formulations.