Content
Handbook H
MT 178 ATTRITION RESISTANCE OF GRANULES
OUTLINE OF METHOD
Prior to the test the granule is sieved on a 125 ìm
sieve in order to remove fine particles. A known amount of this dust-free
granule is transferred to a glass bottle and is then subjected to
a rolling movement with an equal amount of glass beads. After rolling
for a specified
period, the attrition resistance is determined by sieving again on
a 125 ìm sieve and weighing the material retained on the sieve.
SCOPE:
---