Content
Handbook F
MT 159 POUR AND TAP BULK DENSITY OF GRANULAR MATERIALS
OUTLINE OF METHOD
A known weight of sample is put into a glass measuring
cylinder and its volume measured. The cylinder is then raised and
allowed to fall vertically through a distance of 25 mm on to a rubber
pad. The volume is measured again after 100 'taps'.
SCOPE: