Content
Handbook E
SETHOXYDIM
OUTLINE OF METHOD
Sethoxydim is extracted with n-hexane after adding acetic
acid aqueous solution to the sample. The concentration of sethoxydim
is
determined by normal phase high performance liquid chromatography
with UV detection using thymol as internal standard.
SCOPE:
The method is usable for TC and EC formulations.
last update